Kinetics© may be interfaced with patient data systems by passing patient data via the command line.

 

There are 12 fields in the parameter string.  Each field must be followed by the caret symbol (^), including the last field.  The first 11 fields are required.  The drug model name is optional.

 

Required fields

1.User login name
2.Patient name (required format is LastName, FirstName)
3.Medical record number
4.Attending physician name
5.Location (ie, room number)
6.Date of birth (required format is MM/DD/YYYY)
7.Height in cm
8.Weight in kg
9.Gender (M or F)
10.Date SrCr drawn (required format is MM/DD/YYYY)
11.Serum creatinine in mg/dL

 

Optional fields

12. Drug model name

 

An example

[path]\kinwin32.exe Rick Tharp^Clapton, Eric^5895746^King^S3245^01/17/1947^182.9^75^M^1^01/17/2006^Vancomycin CL^

 

 

 